Product-specific engineering analysis
The Hokuyo UST-10LX supplies two-dimensional range scans for navigation. Its horizontal scan plane can miss elevated or low obstacles depending on mounting height.
Where are the angles in a ROS LaserScan message?
In a sensor message, angle_min and angle_increment determine the angle for the element ranges[i]. Convert each valid polar observation into x and y in the sensor frame, then apply the measured transform into base_link.
Check the sensor mounting height and pitch with a thin shelf edge, a curb-height obstacle and an overhanging table. Even a clean planar scan cannot represent everything above and below that plane.
Navigation rangefinder versus protective scanner
A UST-10LX navigation installation should not be presented as a safety-rated protective field without product-level certification and a validated safety chain. If the robot operates around people, define its independent protective devices and the verified stop response. Test glass doors and dark objects separately because their returns can differ from painted walls.
What is the minimum obstacle a UST-10LX can see?
A 2D scanner detects objects intersecting its scan plane. The smallest reliably observed object depends on distance, angular sampling, reflectivity and the detection software. A narrow upright rod can fall between beams at some distances; a table surface above the scanner can remain invisible even when its legs appear in the map.
Build a test corridor with a narrow pole, low threshold and glass door. Mount the sensor at the intended height, then move obstacles across its field and inspect raw scan returns. This reveals geometry and material limitations that a brochure range number cannot resolve.
How should ROS interpret invalid range readings?
LaserScan stores angle_min, angle_increment and a list of measured distances. A point's angle is computed from its array index. Out-of-range or invalid readings should not be silently converted into obstacles at zero distance. Filter them according to the driver's specification, transform valid points to base_link using TF and check timestamp alignment with odometry before debugging the navigation planner.
Does a fast robot need a different UST-10LX mounting position?
The distance available for braking starts at the first reliable observation, not at the sensor's nominal maximum range. A scan placed too high can pass over pallet feet; one mounted too low may be blocked by the robot's own bumper. Measure the position of the scan plane along a real route and compare detected obstacles with a physical tape measure.
Time from a newly appearing obstacle to an updated control command, including the scan period, ROS message queue and local planner cycle. Repeat with the base turning and carrying the expected payload. If a second sensor is added to cover blind zones, document how the controller handles conflicting or stale readings rather than averaging every range measurement.