Robot components · engineering guide

Robot Motors: Servo and Brushless Motor Families

Compare verified servo and brushless motor families used in robot joints, mobile systems and automation equipment.

Engineering analysis and field questions

For an arm joint, motor selection starts with the torque-speed trajectory and the duration at each operating point. Stall torque is not a permissible continuous operating point.

Why a servo advertised with a large load rating burns out

A robot-arm builder asked why servos burned out while lifting a long arm. The static shoulder moment from a 1 kg mass at 0.30 m is about 2.94 N·m under gravity, before adding the link mass and acceleration.

A proper sizing worksheet uses the full kinematic load, worst gravity pose, peak acceleration, expected duty cycle and gearbox losses. Compare the continuous torque-speed curve to the repeated cycle, then check that short peaks fit the manufacturer's allowed duration. A larger peak torque rating can still fail if current limits or heat dissipation are too low.

Diagnosing heat during a stationary hold

A motor can dissipate energy while holding a position because the winding continues to draw current against gravity or a mechanical stop. Check whether the servo is commanded beyond its travel limit, whether the drive is hunting around a target and whether the power supply drops under load. Measure current, voltage and housing temperature through the complete task.

For the motor families in this directory, match winding, feedback encoder and drive configuration before buying. A motor-only SKU differs from a packaged servo actuator with reducer and brake. List the components used in the installed axis so that the published rating refers to the right output shaft.

How does a torque-speed curve change the motor choice?

A motor's available torque is constrained by current, back EMF and the drive's voltage limit. A motor that produces useful torque at low speed may not sustain it at the required top speed. Plot every point in a robot joint's cycle against the chosen motor and drive curve after converting through the gearbox ratio and efficiency.

Separate repeated RMS demand from short acceleration peaks. For a robot elbow, include tool inertia and links downstream of the joint rather than payload mass alone. If the motor is too small at continuous load, changing controller gains cannot create thermal capacity; either change the duty cycle, gearing, cooling or hardware.

Why can adding a brake make the wrist safer but heavier?

A holding brake can keep an axis from falling when electrical power is lost, subject to its stated holding rating and installation. It is not automatically rated to arrest a moving joint at full speed. The brake, wiring and power-loss logic add mass and failure modes, and a robot must decide whether to release the brake before or after producing holding torque.

Test power interruption at a known safe configuration with competent supervision. Document movement under load, restart sequence and how the drive checks brake state. The appropriate choice for a vertical industrial arm may differ from a lightweight mobile manipulator that can safely park its joints.

Products and specifications to verify

These records refer to different configurations. Open the individual product to inspect its interfaces, stated specifications and official source before comparing performance.

maxon EC-i 40

maxon · Brushless DC motor

Brushless EC motor family. Multiple winding and shaft options.

Mechanical interface dependent on configuration

Kollmorgen AKM2G

Kollmorgen · Servo motor

Synchronous servo motor family. Multiple frame and feedback options.

Feedback dependent

SIMOTICS S-1FK2

Siemens · Servo motor

Synchronous servo motor family. Designed for SINAMICS drive systems.

DRIVE-CLiQ options

All robot components