Why a robot can repeat the wrong position
Accuracy describes how close a commanded position is to the achieved position. Repeatability describes how closely repeated attempts cluster under stated conditions. A robot can return to nearly the same incorrect point on every attempt. For fixture-based pick and place, a taught offset may be sufficient; offline programming across a workspace requires attention to absolute positioning.
ISO 9283 defines industrial manipulator performance characteristics and test methods. The simplified two-dimensional illustration in this article is for learning, not a substitute for the complete standard.
A numerical example of systematic error
Suppose a target is (0,0) mm, and five endpoint measurements are (1.8,0.2), (2.0,0.1), (2.1,−0.1), (1.9,−0.2) and (2.2,0.0). The centroid is (2.0,0.0) mm, so its offset is 2.0 mm. The RMS radial scatter about that centroid is 0.20 mm. These two numbers reveal different errors. RMS scatter here is a teaching metric, not the ISO 9283 pose repeatability value.
Subtracting a constant offset can correct the centroid at one pose. It cannot establish accuracy at other positions, orientations or loads; geometric calibration needs data across the intended work envelope.
Identify the source of position error
Measure the tool center point using an independent reference. Repeat at several poses with the same payload, approach direction and speed. Repeat after thermal stabilization and after changing direction. Record both XYZ and orientation when the application depends on tool angle.
Observed error patterns
| Observation | Likely cause to investigate | Diagnostic |
|---|---|---|
| Constant local offset | Tool or fixture reference | Recheck TCP and base frames |
| Error changes across workspace | Kinematic parameters | Measure multiple poses |
| Difference on direction reversal | Backlash or compliance | Approach from both directions |
| Error increases with time | Thermal drift | Log temperature and time |
| Error increases under load | Elastic deflection | Repeat at documented payloads |
What to request from a robot supplier
Ask which performance quantity the datasheet reports, what load and speed were used, whether the robot was warmed up and how the endpoint was measured. A small repeatability number does not establish path accuracy during welding or milling. For high-precision work, test the tool and fixture together rather than treating the bare arm as the entire measurement system.
Frequently asked questions
Can calibration improve repeatability?
It can correct systematic offsets; random scatter, compliance and backlash may require mechanical or control improvements.
Does ±0.02 mm repeatability mean ±0.02 mm absolute accuracy?
No. Read the stated metric and measurement conditions separately.