Engineering analysis and field questions
A six-axis force-torque sensor reports loads in its own measurement frame. The tool's weight, acceleration, zeroing procedure and coordinate transforms affect what a robot interprets as external contact.
An F/T signal that changes before touching anything
A wrist sensor measures the combined wrench transmitted through its installation. When a tool rotates, gravity changes direction in the sensor frame. A static bias measured with one tool orientation is therefore different from compensating the weight of the entire tool across robot poses.
For a contact experiment, record the sensor's zeroing conditions, payload mass, tool center of mass, orientation and sampling rate. Inspect noise when stationary and while accelerating. Then apply a known test load in a known direction. Force and moment ranges must both be considered because a distant contact point can create a large torque from a modest force.
Why a ROS controller says the state interface is missing
The underlying issue concerns the controller's configured state interfaces rather than a physical force measurement.
Check that the simulation exports the expected wrench interfaces, that ros2_control names match exactly and that the controller reads the intended tool frame. When moving to a real sensor, test calibration and overload behavior separately. A working ROS topic does not guarantee correct gravity compensation or contact thresholding.
Can a wrist sensor distinguish gravity from human contact?
Only if the controller has a suitable model and measurements. The sensor sees the combined wrench from the tool's weight, acceleration, cable tension and external contact. Gravity changes direction in the sensor frame as the wrist rotates, even if the operator touches nothing. A zero offset obtained in one pose is therefore inadequate for every pose.
Calibrate the tool mass and center of mass, verify the sensor-to-tool transform and compare model-predicted wrench against measured values in several orientations. Record residual force and moment distributions during normal motion. Set contact thresholds according to this baseline instead of tuning them from a stationary bench test.
Which axis should determine an overload alarm?
All six axes matter. A modest force applied far from the sensor can create a large bending moment. For example, 15 N at a perpendicular lever arm of 0.20 m produces 3 N·m of torque; this is an illustrative calculation, not a product rating. The selected load cell may reach a moment limit before its axial-force range.
Inspect the manufacturer's overload specification and the tool's maximum moment during unexpected contact. A collision test should be performed only within the approved limits and safety procedures. Product accuracy, control latency and personnel-protection certification are separate specifications.